SF146C — Centrifugal Fan
SUNXFAN SF146C series: 3 models. All figures below are manufacturer datasheet values.
Model matrix
| Model | Airflow | Max static pressure | Voltage | Power | Speed | Noise | Speed control |
|---|---|---|---|---|---|---|---|
| SF146C-D092B0-03 | 1200 m³/h | 705 Pa | 310 V DC | 180 W | 1600 r/min | 64±2 dB(A) | 0-6.5V / 4-speed |
| SF146C-E092B1-02 | 1150 m³/h | 675 Pa | 115 V AC | 165 W | 1500 r/min | 60±2 dB(A) | 0-10V/PWM / 0-5V / 0-6.5V / 4-speed |
| SF146C-E092B3-01 | 1250 m³/h | 705 Pa | 230 V AC | 220 W | 1650 r/min | 65±2 dB(A) | 0-10V/PWM / 0-5V / 0-6.5V / 4-speed |
SF146C-D092B0-03 — DC146 Double inlet Centrifugal Fan — 1200 m³/h
Specifications
- Category: Centrifugal Fan
- Motor: DC
- Airflow: 1200 m³/h
- Max static pressure: 705 Pa
- Voltage: 310 V DC
- Power: 180 W
- Speed: 1600 r/min
- Noise: 64±2 dB(A)
- Protection: IP44
- Temperature: -25 °C ~ +60 °C
- Impeller: Galvanised sheet steel
- Bearing: NSK ball bearing
- Speed control: 0-6.5V / 4-speed
- MOQ: 80 PCS
- FOB: FOB Nansha Guangzhou
- Lead time: 25-30 days
FAQ
Q: Why do ERV/HRV units need a 700 Pa-class blower?
A: Because the core is the largest single resistance in the machine: a counterflow plate exchanger plus its pre-filter commonly costs 150–300 Pa clean, and a loading filter roughly doubles that before you add ducts, silencers and the outdoor mesh. At 1,200 m³/h and 705 Pa, this blower keeps the nominal fresh-air rate alive across the whole service interval — the classic failure of undersized fans in HRVs is airflow decaying between filter changes, which quietly wrecks the indoor CO₂ budget.
Q: What does dual-inlet (DIDW) construction buy?
A: One wheel fed from both faces: nearly twice the volume of a single-inlet wheel at equal diameter and speed, which is how 146 mm reaches 1,200 m³/h. The symmetric inflow also cancels most axial thrust, so the NSK bearings run lightly and the assembly keeps its balance at speed. In an ERV or appliance cabinet that means one compact blower replaces two, with a smooth, flat power draw across the range.
Q: 310 V DC or 230 V AC — how do I pick?
A: Follow the power stage already in the unit. The 310 V DC version exists because inverter appliances — heat pumps, ERVs with variable-speed compressors, energy-storage and telecom equipment — already run a rectified DC bus at roughly that level; hanging the blower directly on it deletes an entire AC-DC conversion stage. If the unit plugs into the mains and has no DC bus, the EC versions (115/230 V AC, 1,150–1,250 m³/h, 0-6.5 V or 4-speed) are the cleaner fit. Same chassis, same 705 Pa duty.
SF146C-E092B1-02 — EC146 Dual intake Centrifugal blower — 1150 m³/h
Specifications
- Category: Centrifugal Fan
- Motor: EC
- Airflow: 1150 m³/h
- Max static pressure: 675 Pa
- Voltage: 115 V AC
- Power: 165 W
- Speed: 1500 r/min
- Noise: 60±2 dB(A)
- Protection: IP44
- Temperature: -25 °C ~ +60 °C
- Impeller: Galvanised sheet steel
- Bearing: NSK ball bearing
- Speed control: 0-10V/PWM / 0-5V / 0-6.5V / 4-speed
- MOQ: 80 PCS
- FOB: FOB Nansha Guangzhou
- Lead time: 25-30 days
SF146C-E092B3-01 — EC146 Double inlet Centrifugal Fan — 1250 m³/h
Specifications
- Category: Centrifugal Fan
- Motor: EC
- Airflow: 1250 m³/h
- Max static pressure: 705 Pa
- Voltage: 230 V AC
- Power: 220 W
- Speed: 1650 r/min
- Noise: 65±2 dB(A)
- Protection: IP44
- Temperature: -25 °C ~ +60 °C
- Impeller: Galvanised sheet steel
- Bearing: NSK ball bearing
- Speed control: 0-10V/PWM / 0-5V / 0-6.5V / 4-speed
- MOQ: 80 PCS
- FOB: FOB Nansha Guangzhou
- Lead time: 25-30 days