Medical & Cleanroom Ventilation Fans

Medical devices and cleanrooms have the tightest airflow requirements of any application: the fan must move air quietly, hold a stable flow rate as filters load, and run reliably around the clock. That is why low-noise, electronically commutated blowers are the standard here.

Why low noise and precise airflow matter

How to choose the right model

  1. Noise (dB(A)) — pick the quietest model that still meets airflow; every 3 dB is roughly a halving of sound energy.
  2. Airflow stability — 0-10V/PWM lets the fan track pressure sensors instead of running flat-out.
  3. Protection & material — IP44 + galvanized or PP impeller for wet/humid locations.
  4. Voltage — 24V/48V DC for portable equipment, 115V/230V AC for fixed installations.

FFU (Fan Filter Unit) Integration

An FFU is a self-contained terminal module that pairs its own fan with a high-efficiency filter, drawing room air through the filter and discharging clean air below. SUNXFAN® works with FFU manufacturers as a component supplier — providing EC centrifugal impellers and motor assemblies rather than complete units. Because an FFU ceiling is made up of many modules running side by side, each one has to stay quiet on its own and adjust its speed as part of the group, which is exactly what EC motor technology does best.

Scenario Model Voltage Airflow Power Noise
Portable / battery equipment SF146A-D092A6-02 24 V DC 720 m³/h 80 W 52±2 dB(A)
Quiet 230V, low power SF146A-E092C3-34 230 V AC 780 m³/h 88 W 54±2 dB(A)
115V standard SF146A-E092A1-01 115 V AC 860 m³/h 120 W 60±1 dB(A)
230V standard SF146A-E092A3-02 230 V AC 1080 m³/h 180 W 64±1 dB(A)
48V portable / built-in SF146D-D092A8-01 48 V DC 1020 m³/h 165 W 60 dB(A)
High static, IP44, 310V SF146C-D092B0-03 310 V DC 1200 m³/h 180 W 64±2 dB(A)
High static, IP44, 115V SF146C-E092B1-02 115 V AC 1150 m³/h 165 W 60±2 dB(A)

For filter banks and ducted cleanrooms, the EC forward-curved SF146C double-inlet series adds real static pressure (up to 705 Pa) inside an IP44 housing — ideal where airflow must push through HEPA stages. For point-of-care and portable devices, the 24V SF146A-D092A6-02 delivers quiet, low-power airflow.

Bottom Line

For most lab and medical equipment, the SF146A-E092A3-02 (230 V AC, 1080 m³/h) is the go-to quiet, efficient choice. Where static pressure through filters or an IP44 washdown rating is required, move to the SF146C series. Tell us your airflow target, filter resistance and acoustic limits, and we will confirm the exact model.


Last updated: 2026-11-02